ContractBeam
ContractOpen solicitation — bid to win the work3 days left

Repair 65-Ton Chiller at USCG Air Station Sacramento

Point of contact

Before you bid: ContractBeam aggregates public government data and may lag the official record. Always confirm the scope, deadline, and submission instructions on the official source below before acting.

Related open opportunities

ContractTotal Small Business Set-Aside (FAR 19.5)1 day left

JBSA LAK HVAC Replacement System B4983

NOTICE OF AMENDMENT (PLEASE REVIEW ALL UPDATED ATTACHMENTS): Amendment 0001 The purpose of this amendment is to: 1. Upload Questions and Anwers 2. Provided REVISED Statement of Work dated 4 June 2026 3. Provide Updated Legacy System Photos dated 4 June 2026 4. Provided Amended RFQ - FA301626Q01210001 document that includes the updated attachments and also accounts for two separate contract line items. 5. Change Response Due Date to Tuesday, 9 June 2026 at 10:00AM CDT. ****************************************************************** 26 May 2026 UPDATE : The following have been updated Posted revised RFQ FA301626Q0121 Posted revised Atch 1. SOW_ Legacy R22 Split System Replacement B4983_7May26 Removed Atch 3. Wage Determinations Please continue to monitor SAM.gov for all related updates. All other terms and conditions remain unchanges. ****************************************************************** PLEASE READ CAREFULLY AND FOLLOW ALL INSTRUCTIONS IN THE RFQ ACCORDINGLY! This requirement is being solicited as a 100% Total Small Business set aside. The NAICS code is 238220 Plumbing, Heating, and Air-Conditioning Contractors, PSC 4120 Air Conditioning Equipment and the SBA size standard is $19M. This requirement is for the purchase and installation of a total replacement of Legacy R22 Split HVAC System for B4983 at JBSA LAK 78236 in accordance with (IAW) the associated Statement of Work (SOW). Refer to salient characteristics and technical criteria listed in the attached RFQ. PROJECT OVERVIEW . The contractor shall provide all labor, supervision, materials, equipment, tools, transportation, and quality assurance necessary to remove the existing HVAC system and install a new system meeting current UFC, ASHRAE, NFPA, ICC, OSHA, and Air Force standards. The contractor shall deliver a complete, operational, commissioned HVAC system. Existing equipment : Rheem Condenser, RUUD Air Handler unit. •No front-end control system is installed. •R22 refrigerant system requiring full replacement. •Existing Honeywell controller and wiring to be removed Questions Due Date: All questions must be submitted in writing by email no later than Wednesday, 03 June 2026 at 10:00 AM CDT . Responses to questions will be posted by the Government on the SAM.gov, as received. Questions submitted after this date/time will not be considered. Site Visit: A site visit is scheduled for Tuesday, 02 June 2026 at 10:00 AM at JBSA Lackland Luke East Gate Visitor Control Center, located at B1196, 2602 Luke Blvd 78236. Departure to the site will be promptly at 10:00 AM CDT. Please arrive 45 minutes prior to sign in, wait in line, and retrieve your pass at the visitor center. The Government WILL NOT provide transportation to travel between the sites. Interested parties are required to have a copy of a valid REAL ID Driver’s License, vehicle registration and insurance on hand to receive a base pass. If the drivers license has not been updated to the REAL ID, interested parties will need a passport along with a drivers license. If this type of documentation is not provided a base pass will not be issued and attendance will not be granted. *Requests to attend the Site Visit shall be received NO LATER THAN Tuesday, 26 May 2026 at 10:00 AM CDT and sent to both email addresses detailed below. Contract Specialist (CS) – SSgt Ulysses Solis, ulysses.solis@us.af.mil Contracting Officer (CO) – Emily Rodriguez, emily.rodriguez.8@us.af.mil Contractors who already have base access are required to notify CO & CS via email of planned attendance and check in at the Visitors Center. ATTACHMENTS: Atch 1. SOW_ Legacy R22 Split System Replacement B4983_7May26 Atch 2. Salient Characteristics_15-Ton Commercial DX Split System Atch 3. Legacy R22 Split HVAC System PowerPoint

AgencyDEPT OF DEFENSE
NAICS238220
PlaceDWG, TX
SAM.gov· Posted Jun 4, 2026#FA301626Q0121
ContractTotal Small Business Set-Aside (FAR 19.5)1 day left

NOAA/FCDAS Replacement of Two (2) Non-Operational Boilers

** AMENDMENT 0003 ** The purpose of this amendment is to publish the final, master list of all thirty (30) vendor questions and official Government responses for this solicitation. This document completely replaces and supersedes any prior Q&A attachments, drafts, or versions previously posted or distributed. Offerors are instructed to discard all previous versions and utilize only the text contained within this amendment to formulate their proposals. All other solicitation terms, conditions, and the closing deadline remain unchanged. ** AMENDMENT 0002 ** Offeror Questions & NOAA Responses : A full listing of all offeror questions received regarding this requirement, along with the corresponding answers from NOAA, is now available in the attachment/links section of this posting. The document is titled "FCDAS Boilers Replacement QA." Proposal Deadline Extension : The proposal submission window is now extended in order to allow interested offerors the ability to review the Q&A's to inform and aid in preparation of their proposals. The new deadline to submit a proposal in response to this solicitation is now June 9, 2026, 3:00 PM Eastern Time. ** AMENDMENT 0001 ** Proposal Deadline Extension . The proposal submission window is now extended in order to allow interested offerors the ability to properly and adequately prepare full proposals. The new deadline to submit a proposal in response to this solicitation is now June 5, 2026, 3:00 PM Eastern Time . Site Visit . Due to the demand for site visit, the Fairbanks CDA Station will be hosting a site visit for all interested offerors on Thursday, May 21 at 9:00 AM Alaska Daylight Time. If interested in attending the site visit, vendors must email your interest to NOAA Point of Contacts, Dan Johnson (daniel.l.johnson@noaa.gov), Charles Beaudreault (charles.beaudreault@noaa.gov) and Shabir Choudhary (shabir.choudhary@noaa.gov). When emailing, please be sure to include the following information: Name of company, emails and titles of all personnel planning to attend the site visit with the company. Note: All visitors must provide a government-issued ID to enter the site . Additional Attachments . Drawings of the Facilities Building and the Powerhouse are now attached for reference. Attachements are titled "FCDAS Facilities Building" and "FCDAS Power House" and are located in the attachments/links section of this posting. These drawings are only for familiarizing interersted offerors with the building floor plans; the notes and other information are not relevant to the Boiler Replacement requirement. 1. General Statement: This is a combined synopsis/solicitation for commercial products or commercial services prepared in accordance with the format in FAR Subpart 12.2, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested and a separate written solicitation will not be issued. 2. Solicitation Information: Solicitation Number: 1332KP26Q0033 Requirement: Replacement of two (2) non-operational boilers at the Fairbanks Command Data Acquisition Station (FCDAS), Fairbanks, AK. Procedures: This acquisition is conducted using Simplified Procedures (FAR 12.201-1) . Set-Aside: 100% Total Small Business Set-Aside. NAICS Code: 238220 (Plumbing, Heating, and Air-Conditioning Contractors). 3. Contract Terms and Conditions: The solicitation incorporates provisions and clauses by reference. In accordance with FAR 12.205 , required clauses are identified in the attached RFQ document. The following specific standards apply: Quality: See FAR 12.105 (detailed in PWS). Labor Standards: This project is subject to the Davis-Bacon Act . Wage Determination AK20260001 (Building) is applicable and attached. System for Award Management (SAM): Offerors must be registered in SAM at the time of quote submission. 4. Submission Details: Please see RFQ for submission details. 5. List of Attachments: RFQ_1332KP26Q0033_Boilers_Replac…

AgencyCOMMERCE, DEPARTMENT OF
NAICS238220
PlaceFairbanks, AK
SAM.gov· Posted Jun 4, 2026#1332KP26Q0033